The Model RB478A is a signal converter that receives a 4-20 mAdc input signal from a controller and outputs a relay contact signal to drive a control motor with a built-in feedback potentiometer for position proportioning operation. Also, by setting the center of the angle of rotation and the proportional band for the input signal, split operation is possible.
Archives
High-Torque Modutrol Motor Model: HM
The Model HM modulating motor serves as a high-torque electric actuator to execute either 2-position or proportional control with relay contact signal input. The aluminum alloy housing is rigid, compact, and drip-proof. Internal moving parts are sealed with grease for high efficiency, low running noise, and long lifespan. HM has an internal auxiliary switch, a feedback potentiometer and a clutchless manual handle as optional accessories.
The Model RX-R40/20 – Burner Control Module
The Model RX-_ _ _ combustion safety burner interlock and burner control modules provides safe operation of industrial furnace burners.
Various kinds of interlock monitoring and ignition systems can be realized by the combination of burner interlock modules (RX-L) and burner control modules (RX-R).
In addition, the Model RX-_ _ _ supports the Advanced UV Sensor flame detector for continuous combustion operation, as well as UV sensors for batch operation. Non UL/FM Approved
The Model RX40/20, in combination with the Model RX-L burner interlock module and flame detector, handles ignition operations and flame monitoring. If the burner flame goes out, this module safely executes shutoff. This product supports a variety of flame detectors including the Advanced UV Detector (for continuous/batch operation) as well as flame rods. There are 11 open collector outputs to be used for monitoring, which can be assigned to handle alarms such as ignition failure or flame failure, in addition to the status of the load. These monitor outputs can be directed to the control panel lamps so that the status and situation can be checked onsite during the maintenance or when a sudden problem arises. These functions can be selected easily using the computer loader, without the use of special programs.
The Model RX-L80/90 Burner Interlock Module
The Model RX-_ _ _ combustion safety burner interlock and burner control modules provides safe operation of industrial furnace burners.
Various kinds of interlock monitoring and ignition systems can be realized by the combination of burner interlock modules (RX-L) and burner control modules (RX-R).
In addition, the Model RX- _ _ _ supports the Advanced UV Sensor flame detector for continuous combustion operation, as well as UV sensors for batch operation. Non UL/FM Approved
The Model RX-L80/90, in combination with the burner control module (Model RX-R_ _), executes burner interlock monitoring and prepurge functions. There are 16 inputs for burner interlock. In addition to interlock input, this module can handle batch starting of multiple burners or batch ignition of multiple pilot burners. Status information such as state of the interlocks, alarms, completed purges, etc. can be assigned to 22 transistor outputs and utilized by outputting it to control panel indicator lamps or to a PLC for status monitoring. These functions can be selected easily using the computer loader, without the use of special programs. This product is equipped with RS485 or Ethernet (only RX-L90) for communication. Remote monitoring is possible with this device.
Advanced Ultraviolet Flame Detectors Model: AUD300C
Azbil Model AUD300C Advanced Ultrasonic Flame Detectors is designed to detect ultraviolet radiation from an oil or gas burner flame, for both batch and continuous operations. The AUD300C is used in combination with a dedicated burner controller. By means of the built-in shutter, any mal-function of the UV flame detector or burner controllers is detected by continuous self-checking (Dynamic Self -Check) function, ensuring highly reliable combustion safety control. Ambient temperature 100°C, IP66, vertical mounting possible and wiring distance 200 m Max. Condensing lens available depending on model. Inspection certification and tropicalization treatment options also available depending on the model. UL/FM approved when combined with Model AUR450C Burner Controllers
Multifunction Gateway Communication Controller Model: CMC15G
Azbil Model CMC15G Multifunction Gateway Communication Controllers can connect to Azbil’s digital indicating controllers and flowmeters to host units, including PLCs from other manufacturers. The CMC15GD01A000 advanced model has a logging function. The logging functions (trend, data log, and event log) are helpful for analyzing device failures and carrying out maintenance. You can easily monitor or edit data in the dedicated log viewer. (Available separately)
The Model CMC15G Multifunction Gateway Communication Controller has an RD-232C interface (1 channel), RS-485 interface (3 channels), a dedicated loader port for connection to PC, and A USB port. The controller is easy to set up – setting up simple communication parameters; data can be shared between devices, and instructions can be issued to a controller. Anyone can easily create applications using a dedicated PD application (gateway editor). Types of data, PLC register assignments, and execution timing can be freely set. This product provides flexibility for your system operations. For example, you can select communication cycles according to data update priorities or specific the offer of writing settings. The gateway editor, provided as a PC application, enables you to monitor communication between devices. This function is helpful for onsite adjustments and debugging, including checking the communication execution cycle and pinpointing errors in settings that cause communication problems.
INTELLPAK Signal Distributor Model: IP50DBE/DBC
Azbil INTELLPAK Converter Model IP50DBE/DBC is a signal distributor for supplying electric power to a 2-wire on-site transmitter and extracting standard 4-20 mA DC or 1-5 Vdc signals from the transmitter.
INTELLPAK DC Converter (non-isolation type) Model: IP50DCD
The INTELLPAK Model IP50DCD is a thin plug-in non-isolated DC converter used to amplify and convert input signals at a varying level to a standard signal for a measurement control system.
INTELLPAK DC Isolator Model: IP50DCS/DCE
The INTELLPAK Model IP50DCS and Model IP50DCE are thin, plug-in type DC isolators used to isolate input, output, and power supplies mutually. Each signal level is isolated from the other circuits. The input signals are amplified and converted to a single standard that is output for use in a measurement control system.
INTELLPAK Gradient Response Computing Unit Model: IP50DRA/DRC
The INTELLPAK Model IP50DRA and Model IP50DRC are thin plug-in gradient response computing units that produce a DC signal output changing at a fixed gradient against an input DC signal. If the input signal changes at a rate higher than the preset gradient, the output signal changes at the set gradient, but the output follows the input if the change is slower than the preset gradient.
INTELLPAK First-order Computing Unit Model: IP50FLA/FLC
The INTELLPAK Model IP50FLA and Model IP50FLC are thin plug-in first-order delay computing units that produce a DC signal output after a first-order delay is processed for the DC signal input.
INTELLPAK Monitor Switch Model: IP50MSS/MSD
The INTELLPAK Model IP50MSS and Model IP50MSD are thin plug-in monitor switches that generate a signal by opening and closing relay contacts or turning an open collector output on and off if an input signal surpasses a set value.
INTELLPAK Reverser Model: IP50RVA/RVC
The INTELLPAK Model IP50RVA and Model IP50RVC are thin plug-in reversers that produce a reversed DC signal output from a DC input signal. For example, in the case of a 4-20 mA signal, a 4 mA would be reversed to become a 20 mA output, and a 20 mA would become a 4 mA output signal.
INTELLPAK Selector Model: IP50SL/SH
The INTELLPAK Model IP50SL and Model IP50SH thin plug-in selectors receive two DC signal inputs and generate an output by automatically selecting either the high signal (high selector) or the low signal (low selector).
INTELLPAK Square Root Extraction Computing Unit Model: IP50SQA/SQC
The INTELLPAK Model IP50SQA and Model IP50SQC thin plug-in square root extraction computing units receive a DC signal input having square-law characteristics and generate a DC signal output equivalent to the square root of the input signal.
Model SR-106 Hybrid Multi-Point Recorder
The Model SR100 Hybrid Recorder is a 6-point recorder with an LCD digital display for easy reading of measured values also recorded on folding chart paper. This recorder has three modes for displaying measured values: 1-point digital display, multi-point batch digital display, and digital display + bar graph display.
Various setting for measurement and recording can be easily checked on the LCD digital display using the keys on the front panel.
Model SR-101/102/103/104 Hybrid Pen Type Recorder
The Model SR-101,SR-102, SR-103, and SR-104 Hybrid Recorders are pen type recorders with an LCD digital display for easy reading of measured values recorded on folding chart paper. This recorder has three modes for displaying measured values: 1-point digital display, multi-point batch digital display, and digital display + bar graph display.
Various setting for measurement and recording can be easily checked on the LCD digital display using the keys on the front panel.
Paperless Recorder (6/12 channels) – Model ARF100
Azbil’s Model ARF100 Paperless Recorder (6/12 channels) is a highly visible 5.6 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling range of 100 ms for all channels and a precision of ± 0.1% are achieved, and measured data can be stored in internal memory or on a CF (CompactFlash) card allowing storage up to 2 GB data to be recorded and saved. The CF (CompactFlash) card slot is provided as a standard feature. The user can choose from real time, historical trend display, bar graph display, and numeric display according to the specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Dedicated keys for specific functions are arranged on the keyboard for improved operability. A USB port is also provided on the front panel to enable writing of various settings or data files to a PC, for example, from the recorder. Ethernet capability is supported as standard. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. The following additional options are also available depending on the model: 12 Relay outputs (1 a normally open contacts) model available, 8 non-voltage contact inputs + 8 alarm MOS relay outputs, inspection result included and traceability certificate included. Please consult specification in the documents tab.
Paperless Recorder (12/24/36/48 channels) Model: ARF200
Azbil’s Model ARF200 paperless recorders (12/24/36/48 channels) adopts a highly visible 12.1 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling rate of 100 ms for all 48 points* and a precision of ±0.1% are achieved, and measured data can be stored in internal memory on a memory card (CF or compact flash and USB memory). A CF (CompactFlash) slot and USB port are provided as standard as external memory. Network capability enables monitoring in a web browser running on PCs on the network. Data files can also be sent by e-mail. You can choose from real time/historical trend display, bar graph display, and numeric display according to your specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Ethernet capability is supported as standard. Use of touch screen panel and exclusive keys for each function keeps operation simple and eliminates the need for a manual. The trend screen can be scrolled by touch operation, and comments can be written on screen with the touch pen provided. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. With Network Instrumentation Modules communication (Ethernet) option, data from the Network Instrumentation Module can recorded, the number of recording points can be expanded, and remote measurement can be performed. A variety of input and output options are available depending on the model. Other options available: with inspection result included, tropical treatment results, with inspection results + tropical treatment, with traceability certificate.
* Supported in input measurement 100 ms specifications”
Multi-loop Controllers Without Display – Network Instrumentation Module Communication Module Model: NX-D15
The Network Instrumentation Module Communication Module Model NX-D15 make optimal distributed configuration a reality.
The Controller Module is capable of controlling 2 channels or 4 channels with full multi-inputs. Control actions include continuous proportional PID, time proportional PID, and position proportional PID (D35 2 channel module only). Control outputs include transistor, current, voltage, and motor outputs.
¼ DIN Single Loop Controller Model: C45A
The Model C45A Single Loop Controller is a highly advanced, high-precision compact indicating controller featuring a 5-digit display LED, an input sampling cycle of 25 ms, indication accuracy of +/-0.1% of reading, and up to 2 control loops.
It offers PID control using the latest “RationaLOOP PID” (Ra-PID) and “Just-FITTER” algothms. Up to 5 control outputs (depending on model) are available, selectable from relay contact, voltage pulse, motor drive (triac), DC current/voltage, and transmitter power (24 Vdc).
¼ DIN Single Loop Digital Controller Model: C46A
The Model C46A Single Loop Controller is a highly advanced, high-precision compact indicating controller featuring a 5-digit display LED, an input sampling cycle of 25 ms, indication accuracy of +/-0.1% of reading, and up to 2 control loops.
It offers PID control using the latest “RationaLOOP PID” (Ra-PID) and “Just-FITTER” algothms. Up to 7 control outputs (depending on model) are available, selectable from relay contact, voltage pulse, motor drive (triac), DC current/voltage, and transmitter power (24 Vdc).
¼ DIN Single Loop Digital Controller Model: C45V
The model C45V Single Loop Controller is a highly advanced, high-precision compact indicating controller featuring a 5-digit display LED, an input sampling cycle of 100 ms, indication accuracy of +/-0.1% of reading, and up to 2 control loops. It offers PID control using the latest “RationaLOOP PID” (Ra-PID) and “Just-FITTER” algothms. Up to 5 control outputs (depending on model) are available, selectable from relay contact, voltage pulse, motor drive (triac), DC current/voltage, and transmitter power (24 Vdc).
¼ DIN Single Loop Digital Controller Model: C46V
The Model C46V Single Loop Controller is a highly advanced, high-precision compact indicating controller featuring a 5-digit display LED, an input sampling cycle of 100 ms, indication accuracy of +/-0.1% of reading, and either 2 full multi-range analog inputs or 1 full multi-range plus 2 DC current/voltage analog inputs.
A dual-input computation function can be used for each input and output processing unit, allowing sensor input changeover, control based on the average of 2 PV values, control output changeover, feed-forward control, override control, etc. In addition, the input processing unit has a temperature pressure correction function (2-input model: input temperature correction or pressure correction).
Network Instrumentation Module Communication Module Model: NX-D25
The Network Instrumentation Module Communication Module Model NX-D25 make optimal distributed configuration a reality.
The Controller Module is capable of controlling 2 channels or 4 channels with full multi-inputs. Control actions include continuous proportional PID, time proportional PID, and position proportional PID (D35 2 channel module only). Control outputs include transistor, current, voltage, and motor outputs.
Network Instrumentation Module Communication Module Model: NX-D35
The Network Instrumentation Module Communication Module Model NX-D35 make optimal distributed configuration a reality.
The Controller Module is capable of controlling 2 channels or 4 channels with full multi-inputs. Control actions include continuous proportional PID, time proportional PID, and position proportional PID (D35 2 channel module only). Control outputs include transistor, current, voltage, and motor outputs.
Network Instrumentation Module Digital Input Module Models: NX-DX1 and NX-DX2
Azbil NX-DX1 and NX-DX2 Network Instrumentation Controller Module models make optimal distributed configuration a reality.
Distributed modules execute cooperative control using Ethernet connectivity. This instrumentation offers an excellent solution for productivity and energy conservation needs. Digital input modules can accept pulse input, depending on the model. (High-speed pulse input: 5 kHz, low-speed pulse input: 100 Hz) Pulse totalization is available for energy monitoring needs, such as power or flow rate monitoring. In addition, pulse input can be converted into instantaneous values. Since the SLP-NX Smart Loader Package can be connected via Ethernet, Network Instrumentation Modules can be set up and monitored over an Ethernet communications network.
Network Instrumentation Module Digital Output Module Models: NX-DY1 and NX-DY2
Azbil NX-DY1 and NX-DY2 Network Instrumentation Controller Module models make optimal distributed configuration a reality.
Distributed modules execute cooperative control using Ethernet connectivity. This instrumentation offers an excellent solution for productivity and energy conservation needs. You can select a type of output that depends on the module type (transistor sink type, transistor source type) Logical arithmetic is available for each output. 32 groups of logical operations are provided. Since the SLP-NX Smart Loader Package can be connected via Ethernet, Network Instrumentation Modules can be set up and monitored over an Ethernet communications network.
Network Instrumentation Supervisor Communication Module Models: NX-S11, NX-S12, and NX-S21
Azbil NX-S11, NX-S12 and NX-S21 Network Instrumentation Controller Module models make optimal distributed configuration a reality.
Distributed modules execute cooperative control using Ethernet connectivity. This instrumentation offers an excellent solution for productivity and energy conservation needs. Supervisor modules, in combination with controller modules, realize the following three multi-loop cooperative control functions: Zone temperature difference control, Optimal start-up control, Peak power suppression control. In addition, advanced control algorithms can be applied by merely setting parameters. Since the SLP-NX Smart Loader Package can be connected via Ethernet, Network Instrumentation Modules can be set up and monitored over an Ethernet communications network.
Networks Instrumentation Module Communication Adaptor, Terminal Adaptor Models: NX-CB1, NX-CL1, NX-CR1, NX-TL1, and NX-TR1
Azbil Networks Instrumentation Module Communication Adaptor, Terminal Adaptor Models NX-CB1, NX-CL1, NX-CR1, NX-TL1, and NX-TR1 Network Instrumentation Modules make optimal distributed configuration a reality. Distributed modules execute cooperative control using Ethernet connectivity. This instrumentation offers an excellent solution for productivity and energy conservation needs. The terminal adapter is used for Ethernet chain ring connections (using side connector) No power supply is needed.
¼ DIN Single Loop Digital Controller Model: C25
The Model C25 is a 48 x 96 mm single loop, compact digital controller featuring multi-range inputs and a PID control system using the new “RationaLOOP PID” (Ra-PID) and “Just-FiTTER” algorithms. Up to 2 control outputs are available depending on model selectable from relay contact, voltage pulse, and current. This is a panel-mounted controller with high visibility LED readouts and compatible with the Azbil Smart Loader Package (SLP), which facilities setup, backup, and monitoring for the entire C15/25/26/35/36 line.
Plastic Safety Interlock Switch with Solenoid Lock Model: LJS-TE
Azbil’s Model LJS-TE Solid Compact Plastic Safety Interlock Switches have a forced opening mechanism, UL/CSA/CE markings and a superior IP67 seal. The series have a wide operating temperature range (-25°C to 70°C). The LJS-TE plastic safety interlock switches with Solenoid Lock have double-insulation structure with plastic house (no grounding line connection required). Compatible with straight, right angle and adjustable tongued keys. Tongued Keys are sold separately.
Plastic Safety Interlock Switches Model: LJS-PA_ _ _
Azbil Model LJS-PA_ _ _ Plastic Safety Interlock Switches have a forced opening mechanism, UL/CSA/CE markings, and a superior IP67 seal. The switches are offered with a wide operating temperature range of – 17° F to 158º F (-25° C to 70° C). The Model LJS-PA_ _ _ plastic safety interlock switches compact design has a double insulated structure with plastic housing, so no grounding line connection is required. The switches have different contact configurations and are compatible with straight, right, and adjustable tongued keys. Tongued Keys are sold separately.
Die-Cast Safety Interlock Switches Model: LJS-A_ _ _
Azbil Model LJS-A_ _ _ Die-Cast Safety Interlock Switches have a forced opening mechanism, UL/CSA/CE markings, and a superior IP67 seal. The switches are offered with a wide operating temperature range of – 17° F to 158º F (-25° C to 70° C). The Model LJS-A _ _ _ die-cast safety interlock switch is compatible and has a straight, right, and adjustable tongued key. Tongued Keys are sold separately.
¼ DIN Single Loop Digital Controller Model: C35
The Model C35 is a 48 x 96 mm single loop, digital controller featuring multi-range inputs and a PID control system using the new “RationaLOOP PID” (Ra-PID) and “Just-FiTTER” algorithms. Up to 2 control outputs are available depending on model selectable from relay contact, voltage pulse, continuous voltage and current. This is a panel mounted controller with high visibility LED readouts and compatible with the Azbil Smart Loader Package (SLP), which facilities setup, backup, and monitoring for the entire C15/25/26/35/36 line.
Cable with Connector Model: PA5
The Model PA5 connector with cable is a machine-building industry standard in the automobile industry. Switching to the Model PA5 reduces wiring labor, ensures shorter replacement times, and is perfect for flexible production lines. Usable in harsh environments and exposed to cutting oils, the connectors are extremely useful in welding environments reducing still viable proximity sensor replacement due to poor splicing.
Connector with Cable – DC power supply, vinyl-insulated cord with high resistance to oil and vibration (UL/NFPA79 CM, CL3), cable length 2 m, 4 leads – 1: brown, 2: white, 3: blue, 4: black.
Quick-lock Cable with Connector Model: PA7
The Model PA7 is a quick lock cable with connector that connects with just a 1/8 turn of the lock ring which enables a significant reduction in time and wiring labor. The model PA7 uses the highly compatible M12 threaded connector and UL/NFPA79-compliant cable (CM). Select from a large variety of quick-lock connector types and cable lengths.
Quick-lock Connector with Cable – DC power supply, vinyl-insulated cord with high resistance to oil and vibration (UL/NFPA79 CM, CL3), cable length 2 m, 4 leads – 1: brown, 2: white, 3: blue, 4: black. Compatible with OMRON Smartclick connectors. Smartclick is a registered trademark of OMRON Corporation.
1/8 DIN Single Loop Digital Controller Model: C15
The Model C15 is a 48 x 48 mm single loop, compact digital controller featuring multi-range inputs and a PID control system using “RationalLOOP PID” (Ra-Pid) and “Just-FiTTER algorithms. Up to 2 control outputs are available depending on the model selectable from relay contact, voltage pulse, and current. Panel and socket mounting types are available, and all are compatible with the Azbil Smart Loader Package (SLP), which facilities setup, backup, and monitoring. ±0.5% FS accuracy. The input types can be changed among the thermocouple input group, RTD group, and linear group. Heat and cool control can be achieved using two control outputs. 18 kinds of operations, such as (SP) value selection, RUN/READY selection, and latch cancellation, etc. can be set using to external switch inputs. The process Variable (PV) value can be corrected.
The controller uses 3-wire RS-485 communications. Up to eight points can be registered for the parameter keys. Up to three event outputs are provided. In addition to temperature events, such as PV, DEV, and SP, status events, such as CT heater, over-current, and loop diagnosis can also be set. Personal computer loader option available makes it possible easily perform various settings, such as setup and parameter setting and easily achieve data logging from single unit to up to eight units. CE compliant. cUL compliant depending on the model.
¼ DIN Single Loop Digital Controller Model: C26
The Model C26 is a 96 x 96 mm single loop, digital controller featuring multi-range inputs and a PID control system using the new “RationaLOOP PID” (Ra-PID) and “Just-FiTTER” algorithms. Up to 2 control outputs are available depending on model selectable from relay contact, voltage pulse, and current. This is a panel mounted controller with high visibility LED readouts and compatible with the Azbil Smart Loader Package (SLP), which facilities setup, backup, and monitoring for the entire C15/25/26/35/36 line.
¼ DIN Single Loop Controller Model: C36
The Model C36 is a 96 x 96 mm single loop, digital controller featuring multi-range inputs and a PID control system using the new “RationaLOOP PID” (Ra-PID) and “Just-FiTTER” algorithms. Up to 2 control outputs are available depending on model selectable from relay contact, voltage pulse, continuous voltage and current. This is a panel mounted controller with high visibility LED readouts and compatible with the Azbil Smart Loader Package (SLP), which facilities setup, backup, and monitoring for the entire C15/25/26/35/36 line.
Stainless Steel Limit Switches Model: 1LS_J401
Azbil Stainless Steel Limit Switch Model 1LS_J401 is custom made for continuous use underwater and other harsh environments. They are used in harbor facilities, chemical plants, dams and floodgates because of their superior resistance to salt and corrosive gases — Roller lever, adjustable roller lever type, and without lever models available.
Stainless Steel Sensing Face Cylindrical Proximity Sensors Model: FL7S
The Model FL7S Stainless Steel proximity sensors have a built-up sensing face integrated into a stainless-steel housing, giving it a superior high shock and abrasion resistance. The sensors have a spatter and slag proof special coating and built-in electromagnetic field noise elimination circuit that makes them ideal for welding environments. The integrated sensing face also holds up well in other environments where you have part-to-sensor contact.
Waterproof Vertical Type 2 Point Detection Limited Switches Model: VCL – _ _
Azbil Model VCL- _ _ Waterproof Vertical Type 2-Point Detection Limited Switches have two sets of SPDT built-in switches that enable use as a 2-point detection switch or multi-circuit control switch – center neutral or multi-circuit control switch, depending on the model. The center-neutral model is used for 2-point control. The simultaneous control model is used for multi-circuit control—this is an old school big and heavy switch that is often used in control valve applications and harsh environments. The limit switches have high sensitivity (pretravel=10°, movement differential = 3°)
Ultra Long Life General-Purpose Compact Limit Switches Model: 1LS-J7_ _
Azbil Model 1LS-J7_ General Purpose Ultra Long Life Compact Limit Switches have an onsite mechanical life 3 times that of conventional models, providing improved reliability that drastically reduces minor line interruptions. Improved sliding action and corrosion resistance prevents the actuator return failure enabling a mechanical life of at least 30 million operations. To ensure a tight seal, the wiring to the switch is by connector (Conventional G1/2 conduit/switch terminal wiring type is also available). At-a-glance fluorescent setting indication prevents faulty initial set-up. UL/CSA/GB (CCC marking) certified models available.
The model 1LS-J7_ General Purpose Ultra Long Life Compact Limit Switches are ideal for a wide range of applications, including automobile production facilities and related equipment, special-purpose machine tools, conveyors, casting & welding, automatic assembly machines, and general industrial machinery.
Limit Switches with Positive Opening Mechanism Model: LJA_ _ _
Azbil Model LJA_ _ _ Snap Action Limit Switches with Positive Opening Mechanism enable general industrial machines to comply with EC directives, acquire CE markings and help in the acquisition of EN approval. Limit Switches conform to EN 50041 standard. The model LJA_ _ _ has N/C//N.O. electricity independent contacts (Zb). The use of a twin-contact structure improves contact reliability. Mounting center dimensions are compatible with most LS general purpose limit switches. Standard roller lever, adjustable roller lever, and boot seal roller plunger actuator type models are available. A high degree of sealing meets immersion proof (JIS)and IP67 (IEC 60529) standards. UL, CSA, TUV, and CQC certified.
Compact plastic limit switch with positive opening mechanism Model: LJK-N_ _
Azbil Model LJK-N_ _ Compact Plastic Limit Switch with Positive Opening Mechanism meet standards worldwide. These cost-effective and reliable compact switches conform to IEC standards and are certified by UL and CSA (excluding some models) for equipment and factories to be exported anywhere globally. Positive opening mechanism forces contact open (except for steel wire and spring rod types) and can prevent problems caused by contact fusing. The limit switches can also be used as a safety limit switch. A wide range of actuators is available. Consult specifications for more details.
General Purpose Compact Limit Switches Model _LS_ _
Azbil General Purpose Compact Limit Switch Model _LS_ _ has been an industry standard for decades. These general purpose limit switches have a robust construction and are available in an extensive range of models for use in a wide variety of applications. They are a 2-circuit double break basic switch (DPST)with a rugged die-cast aluminum case with an oil, water, and dustproof housing. A wide range of options includes neon, LED, gold-plated contacts, double seal, long-life, corrosion-resistant, heat-resistant, cold-resistant, spatter guarded, connector type, and more.
Compact Plastic Safety Interlock Switches Model: LJH- _ _ _
Azbil Model LJH-_ _ _ Compact Plastic Safety Interlock Switches have a forced opening mechanism, UL/CSA/CE markings, and a superior IP67 seal. The switches are offered with a wide operating temperature range of – 17° F to 158º F (-25° C to 70° C). The Model LJH-_ _ _ compact plastic safety interlock switches conform to EN 60947-5-1, UL 508, and CSA 22.2.14 standards. Their compact size (78 x 30 x 15 mm) ensures installation anywhere. A special key can be inserted vertically or horizontally. The cable is pre-wired. The switch is compatible with straight, left, horizontal/vertical adjustment(counterclockwise), and horizontal/vertical adjustment (clockwise) tongue keys. Tongued Keys are sold separately.
General Purpose Compact Horizontal Limit Switches Model: SL1-_ _
Azbil Model SL1-_ _ General Purpose Compact Horizontal Limit Switches offer a robust, long-life, and maintenance-free design with a mechanical life of 20 million operations, owing to a two piece-spring mechanism. These maintenance-free switches have a superior seal: oil-resistant/immersion-proof type (JIS) and IP67 (IEC). O-ring and integral diaphragm seal is built-in. The small, space-saving body can be tightly gang-mounted and have high sensitivity (movement differential = 0.1 mm). Contact form sing-pole double-throw (SPDT). Contact type- standard load type: pure silver rivet, low current load type: gold-plate rivet, M3 screw terminal, UL/CSA/GB (CCC marking) certified models available. Rugged models are also available.
The Model SL1-_C General Purpose Compact Horizontal Limit Switches (Rugged) models offer potted switches that protect the conduit and coolant-resistant terminals. The C-spring material high-cobalt alloy, which enhances resistance to coolants. The shape of the diaphragm seals has been modified to prevent cracking and insulation degradation (standard type). The internal plunger with a molded-in diaphragm seal prevents coolant from entering inside. This series offers potted switches that protect the conduit and terminals.
An oil-resistant/immersion-proof version with O-ring and built-in diaphragm seal is also available. The small, space-saving body can be tightly gang mounted, and this high sensitivity single-pole double-throw (SPDT) switch is available in standard (silver) and low current (gold) contact forms.
2-Point Detection Explosion-Proof Limit Switches Model: VCX-7_0_
Azbil Model VCX-7_0_ 2-Point Detection Explosion-Proof Switches are compact vertical gas/steam explosion-proof limit switches for outdoor use. They have a 2-point detection and a pressure-resistant and increased-safety structure, conforming to IEC standards that are usable in a hydrogen gas atmosphere. Models are available that are ATEX (Europe), TIIS (Japan), NEPSI (China), KOSHA (Korea), CNS (Taiwan), IECEx, and NK (shipping) certified. These switches have a lightweight and robust die-cast cover made of an aluminum alloy. The die-cast surface with rust prevention treatment and a baked finish offers corrosion resistance and weather resistance. We also offer Corrosion-resistant models made of die-cast anti-corrosive aluminum and center-neutral and simultaneous operation type models. A single limit switch can detect two limit points (valve upper and lower limits) with the center-neutral type since two different internal switches operate depending on the direction of the actuator rotation.
Vertical Explosion-Proof Limit Switches Model: _LX7000_
The Model _LX7000_ Vertical Explosion-Proof Limit Switches are compact vertical gas/vapor explosion-proof switches for outdoor use, with a pressure-resistant and increased-safety explosion-proof structure, conforming to IEC standards. They are usable in a hydrogen gas atmosphere. ATEX (Europe), TIIS (Japan), NEPSI (China), KOSHA (Korea), CNS (Taiwan), IECEx, NK (shipping) certified models are available. The Model _LX7000_ switches have a light-weight and robust die-cast cover made of aluminum alloy. The die-cast surface with rust prevention treatment and a baked finish offers excellent corrosion and weather resistance. Corrosion-resistant models made of die-cast anti-corrosive aluminum are also available.
The Model _LX7000_ switches are compatible with various actuator head shapes, including roller lever, adjustable roller lever, plunger, roller plunger, fork lever, and non-directional operation types.
Vehicle Mounted Square Proximity Sensor Model: FL2R-V
Azbil Model FL2R-V Square Proximity Sensor were specifically designed with vehicle mounting with high surge resistance. They have a dedicated surge absorption circuit that ensures a high surge resistance of 1 kV. The sensor has a red LED indicator lamp for quick glance understanding and an IP67 seal to improve reliability in vehicle mounting.
DC 3-Wire Square Cylindrical Proximity Sensors Model: FL2
Azbil Model FL2-_ _ _ _ D.C. 3-Wire Square Proximity Sensors can directly switch relays and solenoids with a maximum switching current of 200 mA. A wide variety of models are available, including 4, 7, 12, and 20 mm sizes, top or side sensing, and N.O. or N.C. operations modes. The sensors have a high seal, IP67. Enhanced circuit protection is built in for surge absorption, load short-circuit and reverse connection. Different-frequency types that are only slightly influenced by mutual interference are available for all models. The sensors have enhanced circuit protection, including surge absorption, load short circuit, and reverse connection countermeasures. Sensing distance 4mm to 20 mm depending on the size. Standard (pre-loaded) model dimensions (mm) – Switch package style: 12 x 12 x 45, 15 x 15 x 32, 20 x 20 x 38, 30 x 30 x 52.5, 40 x 40 x 53. Cord length is 1 m.
Amplifier-Contained Compact Square Proximity Sensor Model: APM
Azbil Model APM-_ _ _ _ Amplifier-Contained Compact Square Proximity Sensors thin 5.9 mm (side sensing type) takes up little space and allows them to be installed anywhere. A wide variety of switch types support all kinds of applications. They are 8 mm wide, compact with a 2.5 mm sensing range. Locking boss allows easy mounting by a single screw. A mounting bracket is not required for locking boss models. The indicator lamp is visible from all three directions enabling easy checking of the operating state. DC 3-wire and DC 2-wire models, the sensing distance is 2.5 mm. We offer top and side sensing face models, CE-Marked.
Convergent Laser Measurement Sensor Model: HLB-D130DN
With the Azbil Model HLB-D130DN Convergent Laser Measurement Sensors, very small or thin parts can be detected by differences in distance, unaffected by the color or reflection rate of the target object. The sensor has a small footprint of 12 x 16.3 x 27 mm, precisely detecting minute differences in distance or level. Easy mounting is possible with dedicated brackets included in the packaging. IP65 (IEC standard), CE Marked.
High Accuracy Position Sensors Model: K1G-S07, Model: K1G-S15 and Model: K1G-C04
Azbil High ultra-thin Accuracy Position Sensors Model: K1G-S07, Model: K1G-S15, and Model: K1G-C04 connect to as many as four K1G high accuracy position sensor heads. These sensors include a “test mode:” that allows you to freely switch between analog and digital outputs to check connections before starting the equipment operation. Analog output: 4 outputs, 4 -20 mA, or 1.5 V (all outputs are switched over at once). Digital output: 8 outputs, NPN or PNP transistor (all points are switched over at once). Digital input: 4 inputs, non-voltage contacts, and NPN or PNP open collector (all points are switched over at once).
One sensor can measure up to two positions at a time. A single device can handle different applications simultaneously, including workplace edge position, edge dimensions, hole diameter, and many others eliminating the trouble of selecting devices. Tiny variations and high-speed fluctuations can be reliably detected and visualized – resolutions 0.1 µm, measurement period 250 µs. A built-in function adjusts for minute offsets caused by fluctuations in workspace positions, resulting in high advancement, more accurate detection. Azbil high accuracy position sensor heads sold separately.