Micro Flow Liquid Flow Meters
The Azbil Model F7M Micro Flow Rate Liquid Flow Meter measures a wide range of fluids that do not corrode quartz glass or fluorocarbon resin in industries such as beverages, cosmetics, and water. Applications include: filling (Ex. electrolytic solution), mixing/diluting (Ex. cleaning solutions, chemical agents), spraying (Ex. release agents, steam and sterilization solutions, flux), coating (Ex. Resist solutions, coating agents, flux sealants, circulating (Ex. coolants, lubricants), and extracting/dispensing (Ex. Test reagents, diluted solutions, cleaning solutions in the Biomedical, Bioprocessing, Laboratory Automation, Life Sciences, Liquid Handling Systems, Pharmaceutical, Semiconductor, and Water Treatment Industries. Measuring the flow rate allows for more reliable data management by replacing alternative measures, such as managing the pump rotation speed, measuring the weight, and managing the fluid supply time. In addition, with event functions, it is possible to detect empty pipes and the presence of bubbles and monitors the status of pulsation.
The New Model F7M_-KIT- Low Flow Starter Kit contains a flowmeter, fittings, accessories, and loader program to go straight from unpacking to bench testing or immediate usage in your application.
*Only use with fluids that do not clog the flow path or damage the glass tube or corrode the wetted part materials. If any liquid adheres to the inner surface of the flow path, a measurement error will occur. In addition, if there are bubbles in the fluid or pulsations, output fluctuations or shifts may occur, depending on the amount.
Micro Flow Rate Liquid Flow meter – Model: F7M
Azbil Model F7M Micro Flow Liquid Flow Meters use a thermal flow sensor to monitor low flow liquid flow rates under 50 mL/min: measurement flow…
Model F7M_-KIT- Low Flow Starter Kit with accessories and loader program
The New Model F7M_-KIT Low Flow Starter Kit contains a flowmeter, fittings, accessories, and loader program to go straight from unpacking to bench testing or…
The Azbil Model F7M Micro Flow Rate Liquid Flow Meter measures a wide range of fluids that do not corrode quartz glass or fluorocarbon resin in industries such as beverages, cosmetics, and water. Applications include: filling (Ex. electrolytic solution), mixing/diluting (Ex. cleaning solutions, chemical agents), spraying (Ex. release agents, steam and sterilization solutions, flux), coating (Ex. Resist solutions, coating agents, flux sealants, circulating (Ex. coolants, lubricants), and extracting/dispensing (Ex. Test reagents, diluted solutions, cleaning solutions in the Biomedical, Bioprocessing, Laboratory Automation, Life Sciences, Liquid Handling Systems, Pharmaceutical, Semiconductor, and Water Treatment Industries. Measuring the flow rate allows for more reliable data management by replacing alternative measures, such as managing the pump rotation speed, measuring the weight, and managing the fluid supply time. In addition, with event functions, it is possible to detect empty pipes and the presence of bubbles and monitors the status of pulsation.
The New Model F7M_-KIT- Low Flow Starter Kit contains a flowmeter, fittings, accessories, and loader program to go straight from unpacking to bench testing or immediate usage in your application.
*Only use with fluids that do not clog the flow path or damage the glass tube or corrode the wetted part materials. If any liquid adheres to the inner surface of the flow path, a measurement error will occur. In addition, if there are bubbles in the fluid or pulsations, output fluctuations or shifts may occur, depending on the amount.

Micro Flow Rate Liquid Flow meter – Model: F7M
Azbil Model F7M Micro Flow Liquid Flow Meters use a thermal flow sensor to monitor low flow liquid flow rates under 50 mL/min: measurement flow…

Model F7M_-KIT- Low Flow Starter Kit with accessories and loader program
The New Model F7M_-KIT Low Flow Starter Kit contains a flowmeter, fittings, accessories, and loader program to go straight from unpacking to bench testing or…