Advanced Paperless Recorders Model ARF100/ARF200
Azbil Model ARF100 Paperless Recorder (6/12 channels) is a highly visible 5.6 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling range of 100 ms for all channels and a precision of ± 0.1% are achieved, and measured data can be stored in internal memory or on a CF (CompactFlash) card allowing storage up to 2 GB data to be recorded and saved. The CF (CompactFlash) card slot is provided as a standard feature. The user can choose from real time, historical trend display, bar graph display, and numeric display according to the specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Dedicated keys for specific functions are arranged on the keyboard for improved operability. A USB port is also provided on the front panel to enable writing of various settings or data files to a PC, for example, from the recorder. Ethernet capability is supported as standard. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. The following additional options are also available depending on the model: 12 Relay outputs (1 a normally open contacts) model available, 8 non-voltage contact inputs + 8 alarm MOS relay outputs, inspection result included and traceability certificate included. Please consult specification in the documents tab.
Azbil Model ARF200 paperless recorders (12/24/36/48 channels) adopts a highly visible 12.1 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling rate of 100 ms for all 48 points* and a precision of ±0.1% are achieved, and measured data can be stored in internal memory on a memory card (CF or compact flash and USB memory). A CF (CompactFlash) slot and USB port are provided as standard as external memory. Network capability enables monitoring in a web browser running on PCs on the network. Data files can also be sent by e-mail. You can choose from real time/historical trend display, bar graph display, and numeric display according to your specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Ethernet capability is supported as standard. Use of touch screen panel and exclusive keys for each function keeps operation simple and eliminates the need for a manual. The trend screen can be scrolled by touch operation, and comments can be written on screen with the touch pen provided. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. With Network Instrumentation Modules communication (Ethernet) option, data from the Network Instrumentation Module can be recorded, the number of recording points can be expanded, and remote measurement can be performed. A variety of input and output options are available depending on the model. Other options available: with inspection result included, tropical treatment results, with inspection results + tropical treatment, with traceability certificate.
* Supported in input measurement 100 ms specifications
Paperless Recorder (12/24/36/48 channels) Model: ARF200
Azbil’s Model ARF200 paperless recorders (12/24/36/48 channels) adopts a highly visible 12.1 inch TFT color LCD, incorporates advanced functions, is easy to use, and is…
Paperless Recorder (6/12 channels) – Model ARF100
Azbil’s Model ARF100 Paperless Recorder (6/12 channels) is a highly visible 5.6 inch TFT color LCD, incorporates advanced functions, is easy to use, and is…
Azbil Model ARF100 Paperless Recorder (6/12 channels) is a highly visible 5.6 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling range of 100 ms for all channels and a precision of ± 0.1% are achieved, and measured data can be stored in internal memory or on a CF (CompactFlash) card allowing storage up to 2 GB data to be recorded and saved. The CF (CompactFlash) card slot is provided as a standard feature. The user can choose from real time, historical trend display, bar graph display, and numeric display according to the specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Dedicated keys for specific functions are arranged on the keyboard for improved operability. A USB port is also provided on the front panel to enable writing of various settings or data files to a PC, for example, from the recorder. Ethernet capability is supported as standard. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. The following additional options are also available depending on the model: 12 Relay outputs (1 a normally open contacts) model available, 8 non-voltage contact inputs + 8 alarm MOS relay outputs, inspection result included and traceability certificate included. Please consult specification in the documents tab.
Azbil Model ARF200 paperless recorders (12/24/36/48 channels) adopts a highly visible 12.1 inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling rate of 100 ms for all 48 points* and a precision of ±0.1% are achieved, and measured data can be stored in internal memory on a memory card (CF or compact flash and USB memory). A CF (CompactFlash) slot and USB port are provided as standard as external memory. Network capability enables monitoring in a web browser running on PCs on the network. Data files can also be sent by e-mail. You can choose from real time/historical trend display, bar graph display, and numeric display according to your specific requirements. Various data save modes can be selected such as schedule recording based on day of the week, time and date, or time; or based on recording of data before and after trigger points (e.g. alarms). Data can be saved in CSV or binary format to suit your specific requirements. Ethernet capability is supported as standard. Use of touch screen panel and exclusive keys for each function keeps operation simple and eliminates the need for a manual. The trend screen can be scrolled by touch operation, and comments can be written on screen with the touch pen provided. Ethernet capability enables monitoring in a web browser running on PCs through an intranet or the internet. Data files can be sent by FTP and notifications can be sent by email. Network Instrumentation Modules communication (Ethernet) option available. With Network Instrumentation Modules communication (Ethernet) option, data from the Network Instrumentation Module can be recorded, the number of recording points can be expanded, and remote measurement can be performed. A variety of input and output options are available depending on the model. Other options available: with inspection result included, tropical treatment results, with inspection results + tropical treatment, with traceability certificate.
* Supported in input measurement 100 ms specifications

Paperless Recorder (12/24/36/48 channels) Model: ARF200
Azbil’s Model ARF200 paperless recorders (12/24/36/48 channels) adopts a highly visible 12.1 inch TFT color LCD, incorporates advanced functions, is easy to use, and is…

Paperless Recorder (6/12 channels) – Model ARF100
Azbil’s Model ARF100 Paperless Recorder (6/12 channels) is a highly visible 5.6 inch TFT color LCD, incorporates advanced functions, is easy to use, and is…