Archives

DC 2-Wire Regular Cylindrical Proximity Sensors Model FL7M

Azbil Model F7M DC 2-Wire Regular Cylindrical Proximity Sensors  are available in Polarity Prewired, Quick Lock, and No-polarity models. The sensing distance is 2 mm to 10 mm, depending on the size. Polarity Type Prewired models available in sizes (O.D.) M8, M12, M18, and M30. Cable length 2 m. Quick Lock Prewired models available in sizes (O.D.) M8, M12, M18, and M30. Cable length 2 m. Non-polarity Prewired models available in sizes (O.D.) M8, M12, M18, and M30. Cable length 2 m. Connector cables are available. Prewired 30 cm oil resistance flexible connector cables available in size (O.D.) M8, M12, M18, and M30. Quick Lock 30 cm oil resistant flexible connector cables available in size (O.D.) M12, M18, and M30. No-polarity Prewired 30 cm oil resistant flexible connector cables available in size (O.D.) M12, M18, and M30. Waterproof, sealed to IP67G.

DC 2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors Model: FL7M-A

Azbil Model FL7M-A DC 2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors are certified EN-compliant and can be directly connected to programmable controllers and N.C. units, reducing wiring costs. The sensing distance is 2 mm to 8 mm, depending on the size. Prewired models available are in sizes (O.D.) M12, M18, and M30. Cable length 2 m. Connector Cables are available. Prewired 30 cm oil resistance flexible connector cables available in size (O.D.) M12, M18, and M30. Quick Lock 30 cm oil resistance flexible connector cables available in size (O.D.) M12, M18, and M30. The model FL7M-A DC2 detects workpieces – reliable even if aluminum or cast iron accumulates on the sensing head.

AC/DC 2-Wire Cylindrical Proximity Sensors Model: FL7M

The Model FL7M AC/DC 2-Wire Cylindrical Proximity Sensors rigid structure and highly waterproof DC 2-wire switches have improved visibility of indicator lamps. The Proximity Sensors are no-polarity. They can be used in applications with mixed power availability or just to consolidate part numbers and reduce man-hours. They are compact, and space-saving, sealed to IP67, and the indicator lamp can even be seen from the rear. They also have an enhanced circuit protection built-in.

  • DC 2-wire for reduced wiring costs.
  • The setting indicator shows the stable sensing area
  • The rigid housing allows for higher mounting torque.
  • Firefly glow indicator lamp can be seen from any direction
  • Lowest current consumption in the industry: 0.55 mA
  • Sealed to IP67G
  • Fast time response: 2 kHz

DC 2-Wire Spatter-Guarded Cylindrical Proximity Sensors Model: FL7M

Azbil Model FL7M DC 2-Wire Polarity Prewired, and No-Polarity Prewired Spatter-Guarded Cylindrical Proximity Sensors offer a sensing distance of 3 mm to 10 mm depending on the model. Teflon coating on the housing and a Teflon resin head surface make spatter difficult to stick. Polarity Type Prewired available in sizes (O.D.) M12, M18, and M30. Cable length 2 m. Connector Cables are available. Polarity Prewired 30 cm oil resistance flexible connector cables available in size (O.D.) M12, M18, and M30. Polarity Quick Lock 30 cm oil-resistant connector cables available in sizes (O.D.) M12, M18, and M30. Non-Polarity Type Prewired available in sizes (O.D.) M12, M18, and M30. Cable length 2 m. Connector Cables available Non-polarity Prewired 30 cm oil-resistant flexible connector cables available in size (O.D.) M12, M18, and M30. Non-polarity Quick Lock 30 cm oil-resistant flexible connector cables available in size (O.D.) M12, M18, and M30. The cable is flame-resistant. Noncombustible cable is also available. A variety of anti-spatter measures make these switches ideal for welding processes on the automotive production line.

Amplifier-Contained Compact Square Proximity Sensor Model: APM

Azbil Model APM-_ _ _ _ Amplifier-Contained Compact Square Proximity Sensors thin 5.9 mm (side sensing type) takes up little space and allows them to be installed anywhere. A wide variety of switch types support all kinds of applications. They are 8 mm wide, compact with a 2.5 mm sensing range. Locking boss allows easy mounting by a single screw. A mounting bracket is not required for locking boss models. The indicator lamp is visible from all three directions enabling easy checking of the operating state. DC 3-wire and DC 2-wire models, the sensing distance is 2.5 mm. We offer top and side sensing face models, CE-Marked.

DC 2-Wire Cylindrical Long-Distance No-Polarity Proximity Sensors Model: FL7M

Azbil Model FL7M DC 2-Wire Cylindrical Long-Distance No-Polarity Proximity Sensors offer a sensing distance 4 mm to 15 mm depending on the size. Available in sizes (O.D.) M12, M18, and M30. Cable length 2 m. Prewired 30 mm oil resistance flexible connector cables available in size (O.D.) M12, M18, and M30. Quick Lock 30 cm oil resistant connector cables available in sizes (O.D.) M12, M18, and M30. Waterproof, sealed to IP67G.

DC 3-Wire Cylindrical Proximity Sensors Model: FL7M

Azbil Model DC 3-Wire Cylindrical Proximity Switches have enhanced circuit protection, including surge absorption, load short circuit, and reverse connection countermeasures. The sensing distance is 1.5 mm to 10 mm, depending on the size. The main unit, Firefly indicator, is available in sizes (O.D.) M8, M12, M12 (long-body type), M18, and M30, with NPN and PNP models available for each. The indicator light can be checked even from the rear. IP67 Sealed.

DC 2-Wire Environmental Resistant Cylindrical Proximity Sensors Model: FL7M-C

The Model FL7M-C1 DC 2-Wire Environmental Resistant Cylindrical Proximity Sensors with oil-resistant polyurethane cables are designed for use in harsh environments that cause swelled cables and coolant intrusion in regular sensors. The Model FL7M-C has a special sheathing and an extra seal between the cable and housing that has proved a successful solution to the problem of coolant infiltration along the cable core wires. This sensor is ideal for automobile assembly lines where cables are attacked by coolant.

DC 2-Wire Unshielded Cylindrical Proximity Switches Model: FL7M

Azbil Model FL7M DC 2-Wire Unshielded Cylindrical Proximity Sensors have a long sensing distance of 4mm to 20 mm depending on the size. The DC 2-wire no-polarity function reduces wiring costs. Prewired models are available in sizes (O.D.) M8, M12, M18, and M30. The setting indicator shows the stable sensing area. The proximity switch can be set up to detect objects reliably by bringing the switch progressively closer to the target object and installing the switch at the point where the indicator lamp (N.O. indication) changes from red to green. Cable length 2 m. Prewired 30 cm oil resistance flexible connector cables are available in size (O.D.) M8, M12, M18, and M30. Waterproof, sealed to IP67G.

Liquid Leak Fiber Units Model: HPF-D040

Azbil Model HPF-D040 Liquid Leakage Fiber Unit PFA jacket affords outstanding ease of routing. You can use this unit in an explosion-proof atmosphere because the cable is optical fiber. The unit has a space-saving switch head height of only 9.9 mm and can be used in explosion-proof environments because the cable is optical fiber (carefully check the explosion-proof regulations for location, application, and equipment prior to use). Azbil recommends using the Model HPF-D040 Liquid Leakage Fiber Unit with the Model HPX-AG04 amplifier with output latch. This function effectively detects a small leak of volatile liquid and in early zone/area detection.

General Purpose Photoelectric Sensors with Self-Contained Amplifier Model HP7-_ _ _

Azbil Model HP7- _ _ _ General-purpose Self-Contained Photoelectric Sensors with Self-contained Amplifiers are suitable for a variety of applications and conditions. The general-purpose photoelectric switches have improved resistance to interference (e.g., fluorescent lights). They come in a wide range of configurations and specifications. There are threaded metal mounting holes for more reliable installation. Different frequency thru-scan models are available for stress-free installation. Standard 2mt cable unless specified. CE-marked and UL approved.

  • One button tuning, push with a finger so no awkward body positioning or tools necessary.
  • Industry standard size and hole pattern with a wide variety of cable and connector styles.
  • 4 element LED means powerful range and long life.
  • Excellent resistance to chemical and oil exposure with IP67 rating for wash down protection.
  • Affordable, to meet current market needs
  • Auto-Adjust button for situations where detection is difficult

Background Suppression Photoelectric Sensors Model HP350-G1L: Open Collector NPN and Model HP350-GL2: Open Collector PNP

With the Azbil Model HP350-G1L and Model HP350-G2L Self-Contained Background Suppression Photoelectric Sensors, influence from metal such as aluminum or stainless steel in the background is suppressed. Influence from color variations in the target object is also suppressed. Red light produced a visible spot. A small differential enables thickness detection. Detection occurs at 20 to 200 mm. The set distance is 40 to 200 mm; standard target objects 200 x 200 mm white construction paper. Differential 10% or less (at detection distance). The sensors have a click-action 6 revolution potentiometer—response time 1 ms or less (for operation and return). Output mode open collector NPN and PNP models available. Operating temperature -7.6 °F (-25 °C) to (131 °C) without condensation, operating humidity 30 to 85% RH without condensation, dielectric strength 20 MΩ min. at 500 VDC. IP67 (IEC standard) protective structure. Reverse connection protection. CE Marked

Photoelectric Sensors for Harsh Environments Model HP800 -_ _ _

Azbil Model HP800-_ _ _ Self Contained Photoelectric Sensors for Harsh Environments have a rugged die-cast housing for strength, shock resistance to 1000 m/s2, and a high-performance seal, IP67Gand high- performance seals. They are resistant to most advanced cutting oils passing the JEM IP67G oil resistance tests for oil solutions and 2 types of water-soluble cutting oils which are widely used for tooling processes. Regarding water-soluble cutting oil, the switches pass the product life test by the accelerated test method. Pre-leaded connector models are available. Please refer to the specification in the documentation tab for more details. CE marked; UL approved.

Fiber Units – HPF Models

Azbil HPF Fiber units are available in a wide range of models for various applications and environments. Azbil HPF Contact-Type Liquid Level Fiber Units all-resin structure ensures no metal contamination 4mm diameter allow easy running of cables. Proprietary tip structure prevents liquid from clinging to the top, eliminating a cause of faulty operation. When used with a Model HPX-EG amplifier (sold separately), you can set sensitivity – an easy setup can be done without the process liquid.

Contact-Type Liquid Level Fiber Units Model HPF-D027/ HPF-D033

Azbil Model HPF-D27/HPF-D033 Contact-Type Liquid Level Fiber Unit Photoelectric Sensors all-resin structure ensures no metal contamination. 4mm diameter allows easy running of cables. Proprietary tip structure prevents liquid from clinging to the top, eliminating a cause of faulty operation. The lens built into the tip of the fiber ensures a significant difference in light quantity between the conditions when liquid is present, and liquid is absent. When used with an HPX-EG amplifier (sold separately), you can set sensitivity – easy setup done without the process liquid.

Pipe Mounted Liquid Level Fiber Units Model: HPF-T032/T032E/T034/T034E

Azbil Model: HPT032/T032E/T034/T034E Pipe Mounted Liquid Level Fiber Units provide reliable detection with an array of 16 optical axes that eliminate the effects of air bubbles and water droplets. The unit has a PFA chemical-resistant jacketed fiber and fits a wide variety of pipe diameters. Fail-safe detection can be provided by using different sensing methods (LO/DO) for the upper and lower detection limits in a tank.

Fiber Units for Small Part Passage Detection Model: HPF-T047

Azbil Model HPF-47 Fiber Units for Small Parts Passage Detection provide reliable detection of small parts going through the pipe. Wire lead-out follows the pipe, allows a smaller footprint. By changing the attachment, the width of the detection area can be adjusted to match the pipe diameter. Highly bend-tolerant optical fiber cables are used for operation inside a moving device. Unaffected by light-level changes or stain buildup, the Model HPF-47 Fiber Units for Small Parts Passage Detection provide stable detection. In addition, since the light level differentiation signal is transmitted to a second output, the model provides advanced notice of sensitivity limitations.

Pipe-Mounted Liquid Level Switches with Built-in Amplifier Model HPQ-T1 : Open Collector NPN Transistor and Model HPQ-T2: Open Collector PNP Transistor

Azbil Model HPQ-T1/HPQ-T2 Pipe-Mounted Liquid Lever Fiber Units with Built-in Amplifier provide fail-safe detection of the surface level of liquids. Just mounting the switch on a pipe, the surface of the fluid can be easily detected. Refraction-based detection ensures sufficient gain between light-ON and dark-ON light levels. The switch is also suitable for liquids with poor light transmission (such as photoresist liquid and waste fluids). Depending on the model, units fit on pipe diameters of 1/16”, 3 to 7 mm, and 8 to 13 mm. Indicator and operation selector switches are on the side. Even when gang-mounted, they can be adjusted while viewing the indicator. The same model can be used for upper or lower limit detection (For pipe diameters of 8 mm or less, please contact Azbil North America. Switches with adjustable sensitivity are also available).

Vane Type Photoelectric Sensors with Self-Contained Amplifier Model: HPV-_ _ _

Azbil Model HPV-_ _ _ Vane Type Photoelectric Sensors with Self-Contained Amplifier are guaranteed down to -13 °F (-25 °C) for use in cold storage warehouses. The first optical axis position is located a mere 4mm from the tip of the switch. The sensors have highly visible indicators (for power ON and incoming light). Its light plastic case is 40 x 50 x 10 mm, 60/70 g. small. The photoelectric sensors can be gang-mounted. Sealed to IP64, CE marked.

Sensor models with 2 optical axes save space and reduce wiring in an easy-to-use size (vane width 25 mm, depth 35 mm). The photoelectric sensors operating mode can be set for individual axis with a Light ON/Dark ON selector switch (2-optical axis type).

Digital Fiber Optic Switches Model: HPX-AG__

All Azbil’s Model HPX-AG_ _ Digital Fiber Optic Switches share basic features, including 4-element LED and APC for stable light emission, superior timer functions, and five selectable sensing modes for high accuracy detection as well as model-specific features such as remote tuning, alarm output, dual output, active zone, differential setting, databank, and synchronous external input models. The dual display shows the incoming light level and present value side by side..

Digital Fiber Optic Switches Model HPX-EG00: Standard and HPX-EG01: Remote Tuning

Azbil HPX-EG00 Standard Sensitivity Digital Fiber Optic Amplifiers are equipped with an automatic adjustment function for stable detection with easy operation. To simultaneously display amounts of incoming light and set values, the units have a double digital display. The amplifiers are equipped with usability enhancing functions – automatic sensitivity switching, threshold tracking. All of the Azbil HPX-EG_ _ Digital Fiber Optic amplifiers have: 12 to 24 Vdc + 10%/ – 15% (ripple 10% max) power, current consumption 750 mW max. (30 mA max at 24 Vdc), mutual interference prevention 2 units (at SF mode, nL mode), Output indicator (turn on with output on), sealing IP40 (IEC standard), ambient light immunity. CE-Marked, UL Certified. High sensitivity models are available.

Advanced Temperature Transmitter Model: ATT082

Azbil’s Model ATT082 Advanced Temperature Transmitter provides a high level of functionality, versatility, and safety for the most critical applications in your operation. The Model ATT082 can operate as a single or dual input device with HART® communication.  You can select between dual measurements, hot sensor back-up, differential temperature measurement, sensor drift detection, or average temperature in the dual mode. It is certified by TUV to IEC1508 for use in Safety Instrumented Systems.

These compact and lightweight smart temperature transmitters receive thermocouple input, RTD input, or mV input and transmit it as a 4–20 mA DC or digital signal. They can be used with general-purpose signal cables, like other transmitters for flow or pressure measurement, eliminating the need for compensation wires or three-wire shielded cables, reducing the cost of engineering work increasing the reliability of signal transmission. Self-diagnosis and range setting changes can be done remotely via communication. The optional built-in digital indicator makes it possible to check the temperature or device malfunctions in the field.

 

 Product Overview

  • High Accuracy: see specification for full details based on input type Dual Channel functionality
  • Advanced Diagnostics
    • Sensor failure
    • Sensor drift
    • Corrosion of terminals
    • Low voltage detection
  • Diagnostics per NAMUR NE107
  • LCD local indicator provides both process data and diagnostics information
  • Safe operation in hazardous areas options:
    • FM IS, NI
    • ATTEX II
    • IECEx
  • Several mounting versions and sensor connection combinations available.

HART® is a registered trademark of FieldComm Group

MagneWTM 3000 PLUS+ Detector for Sanitary Applications – Model: MGS28U

  • Tri/IDF clamp connection makes it easy to install or remove the
    detector from piping.
  • The PFA liner is in conformity with FDA (Food and Drug Association) standard.
  • There are no moving parts or obstruction inside the flowtube. The obstruction-less structure is suitable for Cleaning in Place.
  • Internal-insertion style electrodes create no gap between liner and electrodes. The electrode design eliminates the risk of process media residue building up in the gap

MagneW™ is a trademark of Azbil Corporation

MagneWTM 3000 PLUS+ Converter – Model: MGG14C

  • Flexible Digital Communications with HART, DE and Foundation Fieldbus Protocols
  • Intuitive, versatile operator interface with large characters and back-lit LCD dispaly
  • Optional I/O capability for dual range selection input, counter status output and many more!
  • Excelent noise immunity for reliable process control
  • Optional “Fast Response” model for short-run batch applications
  • Averaging function for pulsating flow applications.

MagneW™ is a trademark of Azbil Corporation

MagneWTM 3000 PLUS+ Electromagnetic Flowmeter -Model: MGG18D/F Detector

  • Exclusive high quality lining technology and a special “mirror’fiish” PFA lining offers higher anti-adhession properties than competitive models
  • Lining uses only pure white PFA with no additives
  • Lining is reinforced with stainless mesh and divetailed to flow body providing durablity and long service life in the most difficult applications
  • Flanged detectors available in line sizes from 0.1 inch to 44 inch (2.5 to 1100mm)
  • Wafer style detectors available in line sizes from 0.1 inch to 8 inch (2.5 to 200mm)
  • Field-replaceable electrodes are avialable as standard feature on most models
  • 0.1 in through 8 inch detectors feature all-welded stainless steel construction

MagneW™ is a trademark of Azbil Corporation

Advanced Transmitter for Gauge Pressure

The Advanced Gauge Pressure Transmitter is a microprocessor based smart transmitter that features high performance and excellent stability.  Capable of measuring gas, liquid, vapor, and liquid levels, it transmits 4 to 20 mA DC analog and and digital signals according to the measured pressure.  It can also execute two-way communications between the communicator, thus facilitating self diagnosis, range setting , and automatic zero adjustment.

The Advanced Transmitter Gauge Pressure Transmitters (GTX**G series) are used to measure the pressure of gases, liquids, and steam, as well as to measure tank pressure and fluid levels. They achieve high accuracy of ±0.04 % and long-term reliability (zero drift of only ±0.1 % over 10 years), greatly reducing calibration work after installation. With their very wide measurement range (GTX60G: 35 to 3500 kPa, a rangeability of 1:100), they help to cut costs by reducing the number of devices needed

 

Advanced Direct Mount Pressure Transmitter

  • Unique characterization and composite semiconductor sensor provides high accuracy and stable operation for years to come.
  • Wide rangeability means you can cover more of you applications with less inventory, saving you money.
  • A diverse product offering, including measurement ranges, process connections and working pressure ratings are available to meet your requirments
  • Fast Response time of under 100 msec makes suitable for pressure control in turbine applications
  • User-customizable interface can measure and display in the units you decide are right for your application
  • Bilingual communication capability (HART & DE Protocol) makes the choice for plants with a mixed DCS installed base.

Flange Mount Transmitter for Liquid Level Measurement

  • Unique characterization and composite semiconductor sensor provides high accuracy and stable operation for years to come.
  • Wide rangeability means you can cover more of you applications with less inventory, saving you money.
  • A diverse product offering, including measurement ranges, process connections, working pressure ratings and wetted parts materials are available to meet your requirments
  • Fast Response time of under 100 msec makes the transmitter suitable for pressure control in turbine applications
  • User-customizable interface can measure and display in the units you decide are right for your application
  • Bilingual communication capability (HART & DE Protocol) makes the choice for plants with a mixed DCS installed base.

MagneWTM Two-wire PLUS+ Loop Powered Electromagnetic Flowmeters

  • Enhanced signal conditioning circuitry provides excellent noise and spike immunity
  • High stable and repeatable output with ±0.5% of rate accuracy
  • Minimum process fluid conductivity requirement of 10μS/cm provides maximum applicability
  • Electrode Status Diagnostic function diagnoses empty pipe condition or electrode scaling
  • Available in wafer of flanged designs
  • Both Integral and Remote configurations are available for maximum flexibility
  • Detector sizes from 0.1″ to 8″ (2.5 to 200mm) are available

MagneW™ is a trademark of Azbil Corporation

Advanced Transmitter for Differential Pressure

  • Unique characterization and composite semiconductor sensor provides high accuracy and stable operation for years to come.
  • Wide rangeability means you can cover more of you applications with less inventory, saving you money.
  • A diverse product offering, including measurement ranges, process connections, working pressure ratings and wetted parts materials are available to meet your requirments
  • Fast Response time of under 100 msec makes the transmitter suitable for pressure control in turbine applications
  • User-customizable interface can measure and display in the units you decide are right for your application
  • Bilingual communication capability (HART & DE Protocol) makes the choice for plants with a mixed DCS installed base.

MagneWTM 3000 PLUS+ Explosion proof Electromagnetic Flow Meter Detector – Model: MGG17

  • Exclusive high quality lining technology and a special “mirror’fiish” PFA lining offers higher anti-adhession properties than competitive models
  • Lining uses only pure white PFA with no additives
  • Lining is reinforced with stainless mesh and divetailed to flow body providing durablity and long service life in the most difficult applications
  • Flanged detectors available in line sizes from 0.1 inch to 16 inch (2.5 to 400mm)
  • Wafer style detectors available in line sizes from 0.1 inch to 8 inch (2.5 to 200mm)
  • Field-replaceable electrodes are avialable as standard feature on most models
  • 0.1 in through 8 inch detectors feature all-welded stainless steel construction

MagneW™ is a trademark of Azbil Corporation

Advanced Pressure Transmitter with Remote Diaphragm Seals

Paired with the Advanced Pressure Transmitter, Azbil North America is able to provide an extensive line of Remote Diaphragm Seals. From cryogenic to high-temperature applications, we can draw upon decades of experience designing and manufacturing remote diaphragm seals for process control to find a transmitter/remote seal system that fits your needs.

For application, assistance contact Azbil North America or use the Distributor Locator to find your local representative.

AX2200 and AX2300 Multi-variable Vortex Flow Meters

Multivariable function from a single meter

2 Vortex multi-variable meters from Azbil North America employ three sensing elements in a single meter: a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer. Within this single instrument, you can measure the mass fl ow rates of gasses, liquids, and steam with far more accuracy than with external measurement techniques which may not adequately compensate for dynamic process conditions. With the flexibility to install in almost any location—including hot tapping—you can get precise measurements from nearly any location when you need it.

Multi-variable capability within this single housing can also simplify systems, reduce equipment cost, and ease installation and maintenance hassles . Th e wide variety of options and configurations available ensures that there is a meter for any application requirement.

Advanced Transmitter for Absolute Pressure

Use the new configurator to choose the right options for your application.

  • Unique Characterization and composite semiconductor sensor provides high accuracyand stable operation for years to come.
  • Wide rangeability means you can cover more of your applications with less inventory, saving you money.
  • A diverse product offering, including measurment ranges, process connections, working pressure ratings and wetted parts materials are available to meet your requirements
  • Fast Response time of under 100 msec makes suitable for pressure control in turbine applications
  • User-customizable interface can measure and display in the units you decide are right for your application
  • Bilingual communications capability (HART & DE Protocol) makes the choice for plants with a mixed DCS installed base.