Know Your Flow - Measuring Flow and Energy is Paramount in Improving Energy Efficiency
Selecting and sizing the right flow meter for your application can be the difference between thinking you know your flow and actually knowing your flow.

To Learn More Visit Our Booth at the Virtual CA Facilities Expo November 18th -19th
Pro-V™ Inline and Insertion Vortex Flow Meters
The Pro-V™ multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost, and total cost of ownership over the lifetime of the instrument.
Ideal For:
- Superheated / saturated steam
- Natural gas
- Chilled / hot water
- Energy measurement


Pro-T™ Insertion Turbine Flow Meters
The Pro-T™ multivariable flowmeter uses three primary sensing elements—a turbine sensor, an RTD temperature sensor, and a solid-state pressure transducer—to measure the mass flow rate of gases, liquids, and steam.
Ideal For:
- Steam, gases, and liquids with low flow sensitivity
- Applications with seasonal flow changes
SonoPro® U42 Commercial Series and U43 Water Series Clamp-on Ultrasonic Flow Meters
Ultrasonic transducers are clamped directly onto the outside of the pipe and never directly contact the media inside the pipe
Ideal For:
- Homogeneous clean fluids with little to no air bubbles or particulates
- Applications where cutting into a pipe or shutting down a process isn’t an option—the U42 and U43 are completely non-intrusive and easy to install and set up


SonoPro® S34 Portable Clamp-on Ultrasonic Flow Meters
The handheld S34 SonoPro® Portable can be used in various locations to deliver accurate and reliable flow measurements. With the addition of external temperature inputs, SonoPro® Portable can provide BTU energy or mass flow measurement
Ideal For:
- Homogeneous clean fluids with little to no air bubbles or particulates
- Applications where cutting into a pipe or shutting down a process isn’t an option—the U42 and U43 are completely non-intrusive and easy to install and set up
Different flow meter styles have different strengths and capabilities. We can help you select the right technology for your application.
- Flow meters capture volumetric flow, mass flow, or energy with varying degrees of accuracy and repeatability. It is important to consider how flow data will be used.
- Process Media: Liquids, gases, and steam. Bubbles / particulates etc. affecting performance and meter selection.
- Ideal process conditions don’t exist—pipe dimensions, velocities, pressures, and temperatures, elbows in pipes, and obstructions like control valves all impact a flow profile and thus how well a meter performs. The right meter can minimize negative effects.
- Flow and Energy demands change over time—Seasonal, Weekly, Daily, Hourly, and even instantaneous load requirements. Seasonal loading can mean a given meter works well during the summer but not during the winter.