Control Valve Positioners
Azbil’s Smart Valve Positioners are designed for long-term reliability, universal compatibility, ease of use, and system serviceability. Unique features and advanced diagnostics allow users to not only understand what is happening in the process but also detect abnormalities and deterioration in the valve itself.
Features & Benefits
Reliability – Save money and time through years of trouble-free service:
- A unique isolating body separates the air circuit from the electrical circuit, protecting the positioner from damage caused by intrusion of moisture, oil, and dust.
- A non-contact magnetic rotary position sensor reduces damage caused by frictional wear, for long-term precision control.
Accessibility – These positioners are designed for use across every industry and application for universal process control:
- Positioners are compatible with most commercially-available valves including the Azbil Model AGVB / AGVM; Fisher 657/667; Flowserve Mark 1; and more.
- Information is accessible via a handheld communicator or host system to access parameter setup, alarms, and diagnostic functions with industry-standard communications protocols.
Usability – Positioners easily and quickly auto-calibrate and adjust, saving time and money:
- Depending on the model, auto-calibration is initiated using push-buttons or a simple flat-head screwdriver.
- Auto-calibration assesses valve movements, (upper and lower valve opening limits / travel; stroke time; hysteresis; etc) and adjusts the valve to optimal settings.
Maintainability – Advanced diagnostics detect abnormalities, making condition-based maintenance possible. Available information includes:
- Stick-slip, cycle count, total stroke count, max travel speed, and shut count monitoring.
- Self-diagnostics monitors temperature and overall health of the positioner itself (CPU, ROM, EPM DUTY, etc).
- Travel histogram and zero-point travel comparisons available with Valstaff valve diagnostics software.
- Step response testing and input signal / travel deviation diagnosis.
Smart Valve Positioner 300 Series
For critical chemical applications, you can depend on reliable Smart Valve Positioner solutions from Azbil North America. High accuracy allows for tighter process control and…
Smart Valve Positioner 700 Series
Built-in pressure sensors and a local user interface (LUI) featuring buttons and a local display allow for easy access to valve diagnostics, even without a…
Azbil’s Smart Valve Positioners are designed for long-term reliability, universal compatibility, ease of use, and system serviceability. Unique features and advanced diagnostics allow users to not only understand what is happening in the process but also detect abnormalities and deterioration in the valve itself.
Features & Benefits
Reliability – Save money and time through years of trouble-free service:
- A unique isolating body separates the air circuit from the electrical circuit, protecting the positioner from damage caused by intrusion of moisture, oil, and dust.
- A non-contact magnetic rotary position sensor reduces damage caused by frictional wear, for long-term precision control.
Accessibility – These positioners are designed for use across every industry and application for universal process control:
- Positioners are compatible with most commercially-available valves including the Azbil Model AGVB / AGVM; Fisher 657/667; Flowserve Mark 1; and more.
- Information is accessible via a handheld communicator or host system to access parameter setup, alarms, and diagnostic functions with industry-standard communications protocols.
Usability – Positioners easily and quickly auto-calibrate and adjust, saving time and money:
- Depending on the model, auto-calibration is initiated using push-buttons or a simple flat-head screwdriver.
- Auto-calibration assesses valve movements, (upper and lower valve opening limits / travel; stroke time; hysteresis; etc) and adjusts the valve to optimal settings.
Maintainability – Advanced diagnostics detect abnormalities, making condition-based maintenance possible. Available information includes:
- Stick-slip, cycle count, total stroke count, max travel speed, and shut count monitoring.
- Self-diagnostics monitors temperature and overall health of the positioner itself (CPU, ROM, EPM DUTY, etc).
- Travel histogram and zero-point travel comparisons available with Valstaff valve diagnostics software.
- Step response testing and input signal / travel deviation diagnosis.

Smart Valve Positioner 300 Series
For critical chemical applications, you can depend on reliable Smart Valve Positioner solutions from Azbil North America. High accuracy allows for tighter process control and…

Smart Valve Positioner 700 Series
Built-in pressure sensors and a local user interface (LUI) featuring buttons and a local display allow for easy access to valve diagnostics, even without a…