GO to the azbil Global Site
Search:
HLA Series Laser Measurement Sensor
HLA Series Laser Measurement Sensor



Description

HLA Series


Overview

High Accuracy Distance Measurement by the Direct Reflection Method.


Specifications

Type

Distance Output, Reflective

Catalog Listing

HLA-D130A

HLA-D250A

HLA-D500A

Power Supply

18 to 28Vdc

Current Consumption

120mA

Measuring Range

30 to 130mm

50 to 250mm

100 to 500mm

Focal Spot Diameter

1 to 2mm

2mm

Output

Alarm: PNP output with pull down resistor

Output

Current output: 4-20mA, Voltage output: 0 to 10V, Alarm: 28Vdc 100mA max.

Resolution

0.06mm

0.3mm

0.5mm

Linearity

±0.2mm

±0.9mm

±1.5mm

Response Time

10msecs

Light Emitter

Laser diode, frequency 675nm, Class 2 (21CFR 1040.10)


Benefits

  • Detection of a distant and very small spot; 1 to 2mm at a distance of up to 500mm
  • High accuracy distance measurement; Resolution of up to 0.06mm